FENOTCHMODESEL=FENOTCHFILT, MODE=CONT, ADCATTENMODE=DISABLE
No Description
PWRTARGET | Power Target |
MODE | Mode 0 (CONT): AGC loop is adjusting gain continuously. 1 (LOCKPREDET): Gain is locked once a preamble is detected. 2 (LOCKFRAMEDET): Gain is locked once a sync word is detected. 3 (LOCKDSA): Gain is locked once DSA is detected. |
RSSISHIFT | RSSI Shift |
DISCFLOOPADJ | Disable gain adjustment by CFLOOP |
CFLOOPNFADJ | Enable NF correction term in SL |
CFLOOPNEWCALC | Enable new wanted gain calculation in SL |
DISRESETCHPWR | Disable Reset of CHPWR |
ADCATTENMODE | ADC Attenuator mode 0 (DISABLE): ADC attenuator back-off will not be done by AGC 1 (NOTMAXGAIN): ADC attenuator is backed-off if rxgain is NOT MAXGAIN |
FENOTCHMODESEL | FE notch mode select 0 (FENOTCHFILT): FE notch configured as a filter 1 (FENOTCHATTN): FE notch configured as a atenueator |
ADCATTENCODE | ADC Attenuator code |
ENRSSIRESET | Enables reset of RSSI and CCA |
DSADISCFLOOP | Disable channel filter loop |
DISPNGAINUP | Disable PN gain increase |
DISPNDWNCOMP | Disable PN gain decrease compensation |
AGCRST | AGC reset |